| IEAOPT00 -- Parameters that control resource management algorithms in the System Resource Manager. 
RFC CPU=0.1,IOC=0.1 00000010
RMC ERV=500 00000020 
Parameter in IEASYSxx OPT=xx
Notes The OPT contains two categories of information: Resource factor cofficients: [RFC [CPU=x.x][,IOC=x.x] Resource manager constant: [RMC ERV=xxxxxx]
Syntax Parameters | Keyword | Meaning | Value Range | Default Value | | CPU | Specifies the weighting factor by which the recommendation of the CPU load adjusting function is to be multiplied, when an address space is evaluated for swapping. | 0.0-9.9 | 0.1 | | IOC | Specifies the weighting factor by which the recommendation of the I/O load adjusting function is to be multiplied, when an address space is evaluated for swapping. | 0.0-9.9 | 0.1 | | ERV | Specifies the "enqueue residence value." This is a multiplication factor used to calculate the amount of task execution time during which an address space should not be swapped out. | 0-999999 | 1 |
|